LTA
Series 4-20
mA, 0-20 mA & 0-10V
Analog Output
DIN Rail Transmitters
DIN Rail mounted, digitally
programmable.
Exceptional accuracy at high update rates.

Models by Input
Signal:
Loop Splitters:
- QLS Quad Loop Splitter. Splits on
analog input into up to four independently scalable 4-20 mA output
loops. Outputs can share the same ground.
- TLSA Triple Loop Splitter. Splits one
analog input into up to three independently scalable 4-20 mA output
loops. Outputs cannot share the same ground. Replaced by QLS for new
applications.
Serial Input Transmitter, 4-20 mA or 0-10V Output:
Analog Input Transmitters, 4-20 mA or 0-10V Output:
Pulse Input Transmitters, 4-20 mA or 0-10V Output:
|

Standard
Features, All Models:
- Available for wide
choice of analog, pulse, or serial data inputs
- 4-20 mA, 0-20 mA or 0-10V
transmitter output,
jumper selectable, isolated
- Output resolution:
0.0015% of span (16 bits)
- Output accuracy:
±0.02%
of span
- Output update rate
to 60/sec
- Easy setup with PC-based
Instrument Setup Software
- DIN rail mount housing only 22.5 mm wide
- Detachable
screw-clamp connectors
- 5V, 10V or 24V dc sensor excitation
output, isolated
- Dual solid state relays for alarm or control,
isolated
- RS232 or RS485 serial communications,
isolated
- Universal AC power,
85-264 Vac
Options:
- Extended main board
for custom curve linearization & rate from
successive readings
- Low voltage power
10-48 Vdc or 12-32 Vac
|
|
Three analog outputs are
jumper selectable: 4-20 mA, 0-20 mA or 0-10V. All selections provide
16-bit (0.0015%) resolution of output span and 0.02% output accuracy. Output isolation from signal and power grounds
eliminates potential ground loop problems.
Fast read rate at up to 50
or 60 conversions per second while integrating the signal over a
full power line cycle is provided by Concurrent Slope (Pat 5,262,780)
analog-to-digital conversion for analog input signals. High read
rate is ideal for peak or valley capture and for real-time computer interface and control. Digital
signal filtering modes are selectable
for stable readings in electrically noisy environments. The internal digital readings
and analog output can be individually selected to be either unfiltered or filtered.
Easy Transmitter programming is via
Laurel's Instrument Setup Software,
which runs on a PC under MS Windows. This software can be downloaded from this website at no charge. The required transmitter-to-PC interface cable is available from
Laurel (P/N CBL04).
Laureate
LTA Series 4-20 mA output
transmitters duplicate the performance and extensive programmable
features of their Laureate digital panel meter, counter and timer
counterparts. This allows unique configurations, such as 4-20 mA transmitter
versions of pulse totalizers,
analog totalizers, or quadrature position meters. A unique product is
Laurel's TS6 serial-to-analog
converter transmitter, which converts serial data to an isolated analog
output.
|

|
|
|