Modbus & Serial Output Transmitter &
Totalizer for 0-1 mA, 4-20 mA or 0-10V

 Scalable to flow rate or total flow from process signals.
DIN Rail mounted, digitally programmable.

4-20 mA Current Transmitters for AC RMS Voltage or Current

RoHS Mark

Made in California

Standard Features

  • Selectable Modbus or Laurel ASCII protocol
  • Modbus RTU or ASCII modes, 2-wire connection, up to 247 digital addresses
  • Output rate from 0-1 mA, 4-20 mA or 0-10V analog signals
  • Output totalized rate from 0-1 mA, 4-20 mA or 0-10V analog signals
  • Selectable square root extraction for differential pressure flow transducers
  • Output scalable to six transmitted digits:
    -
    Span adjust from 0 to ±999,999
    - Zero adjust from -999,999 to +999,999
  • Exceptional accuracy: ±0.005% of input span ±1 count
  • Output update rate: 25/sec
  • Peak value capture
  • DIN rail mount package only 22.5 mm thick
  • Plug-in screw-clamp connectors.
  • Easy setup with PC-based Instrument Setup Software
  • 5V, 10V or 24V dc sensor excitation output, isolated
  • Dual solid state relays for alarm or control, isolated
  • 0-10V, 4-20 mA or 0-20 mA analog output, isolated
  • Universal AC power, 85-264 Vac
  • Priced at only $235 (basic totalizer transmitter)
    Options:
  • Extended Main Board for custom curve linearization,
    time based on rate (1/rate).
  • Low voltage power, 10-48 Vdc or 12-32 Vac.

Description

The Laureate Modbus & serial output totalizing transmitter accepts 0-1 mA, 4-20 mA or 0-10V signals from flow meters and other transducers, such as watt meters, to track rate or totalized rate.

  • With a Standard Main Board, the transmitter output can track rate (such as gallons per minute or watts) or totalized rate (such as gallons or kilowatt hours) whether the transducer output is linear or requires square root extraction (differential pressure flow transducers).
      

  • With an Extended Main Board, the transmitter can also perform custom curve linearization (provided by a curvilinear spline fit with up to 180 data points), display 1/ rate (such as the time it takes a conveyor to pass through an oven), and perform batch control for repetitive fill operations.  Such applications typically make use of optional dual solid state relays, which are available as options. External reset of totals is provided by a special connector.

Signal Conditioner Board for Laureate Analog Input Flow Rate Meter and Analog Flow TotalizerA signal conditioner board converts the full-scale 0-1 mA, 4-20 mA or 0-10 V analog signal to a frequency of 10 kHz to 110 kHz. This frequency is determined by measuring period over a selected gate time (from 10 ms to 200 s) and taking the inverse of period. At the lowest frequency of 10 kHz and the minimum gate time of 10 ms, the transmitter is capable of 25 updates per second. Scaling is done mathematically. Totals are stored in nonvolatile memory in case of power loss.

LTM Series serial output transmitters send data via an isolated serial port, which is user configurable for RS232 or RS485 and full or half duplex operation. Three protocols are user selectable: Modbus RTU, Modbus ASCII, or Laurel ASCII. Modbus operation is fully compliant with Modbus Over Serial Line Specification V1.0 (2002). The Laurel ASCII protocol allows up to 31 Laureate devices to be addressed on the same RS485 data line. It is simpler than the Modbus protocol and is recommended when all devices are Laureates. It also allows use of Laurel Datalogging Software.

Standard features of Laureate transmitters include:

  • Serial data output, isolated. User selectable RS232 or RS485, half or full duplex, Modbus or Laurel ASCII protocol.
  • Dual solid state relays for control or alarm, isolated. Rated 120 mA at 130 Vac or 170 Vdc.
  • Transducer excitation output, isolated. User selectable 5V@100 mA, 10V@120 mA or 24V@50 mA.
  • Analog transmitter output, 16-bit, user scalable and isolated. User selectable 4-20 mA, 0-20 mA or 0-10V levels.
  • Universal AC power supply for 85-264 Vac.

Easy Transmitter programming is via Laurel's Instrument Setup Software, which runs on a PC under MS Windows. This software can be downloaded from this website at no charge. The required transmitter-to-PC interface cable is available from Laurel (P/N CBL04).

Specifications
Laureate Modbus & Serial Output Transmitter &
Totalizer for 0-1 mA, 4-20 mA or 0-10V Inputs

Analog Input

0-1 mA 4-20 mA 0-10 V

Input resistance
Max current or voltage

182 ohms
37 mA
9 ohms
160 mA
1 Mohm
600 V

Input Resolution
Span Tempco
Zero Tempco
Accuracy at 25°C

Read Rate

6 digits
±0.0025% R/°C
±0.0005 FS/°C
±0.005% FS ±1 count
25/sec (typical)

Serial Data Output (standard)

Signal levels
Data Rates
Output Isolation
Serial Protocols
Devices on RS-485 Line
Modbus Addresses
Modbus Modes
Modbus Compliance

RS485 (default) or RS232 (jumper selectable)
300, 600, 1200, 2400, 4800, 9600, 19200 baud
250V rms working, 2.3 kV rms per 1 min test
Modbus RTU, Modbus ASCII, Laurel ASCII
32 max without a repeater.
247 max
RTU or ASCII, 2-wire.
Modbus over Serial Line Specification V1.0 (2002)

Transducer Excitation Output (standard)

Output levels
Output Isolation

5V@100 mA, 10 @120 mA, 24V@50 mA (jumper selectable)
50V from signal ground

Dual Relay Output (optional)

Relay Type
Load Rating

Two solid state relays, SPST, normally open, Form A
130 mA at 140 Vac or 180 Vdc

Analog Output (standard)

Output Levels
Compliance, 4-20 mA
Compliance, 0-10V
Output Resolution
Output Accuracy
Output Isolation

4-20 mA, 0-20 mA, 0-10 Vdc (jumper selectable)
10V ( 0-500 ohm load )
2 mA ( 5 kOhm load or higher)
16 bits (65,536 steps)
0.02% of output span plus conversion accuracy
250V rms working, 2.3 kV rms per 1 minute test

Power Input

Standard Power
Low Power Option
Power Frequency
Power Isolation
Power Consumption

85-264 Vac or 90-300 Vdc (DC operation not UL approved)
10-48 Vdc or 12-32 Vac
DC or 47-63 Hz
250V rms working, 2.3 kV rms per 1 min test
2W typical, 3W with max excitation output

Mechanical

Dimensions
Mounting
Electrical Connections

120 x 101 x 22.5 mm
35 mm rail per DIN EN 50022
Plug-in screw-clamp connectors

Environmental

Operating Temperature
Storage Temperature
Relative Humidity
Cooling Required

0°C to 55°C
-40°C to 85°C
95% at 40°C, non-condensing
Mount transmitters with ventilation holes at top and bottom.
Leave 6 mm (1/4") between transmitters, or force air with a fan.

Pinout
Laureate Modbus & Serial Output Transmitter &
Totalizer for 0-1 mA, 4-20 mA or 0-10V Inputs

Ordering Guide
Laureate Modbus & Serial Output Transmitter &
Totalizer for 0-1 mA, 4-20 mA or 0-10V Inputs

 Click on the radio buttons to build a model number with pricing (shown below the Ordering Guide).

  Quantity
Transmitter
Type
LTM  Laureate Transmitter, Modbus or Laurel ASCII protocol $235
Main
Board
Standard Main Board
Extended Main Board
NC
$40
Power Isolated 85-264 Vac
Isolated 10-30 Vac or 10-48 Vdc
NC
$30
Relay
Output
None
Isolated Dual Solid State Relays
NC
NC
Analog Output None
Isolated 4-20 mA, 0-20 mA or 0-10V Analog Output
NC
NC
Input
Type
VF1  V-to-F Converter, 4-20 mA
VF2  V-to-F Converter, 0-1 mA
VF3  V-to-F Converter, 0-10 V
NC

With Standard Main Board: Rate, square root of rate, or total from differential pressure flow transducers with a DC output.
With Extended Main Board: Above plus linearization of nonlinear inputs, 1/rate (time).

Accessories CBL04  RS-232 cable, LTM to computer or USB adapter
CBL02  USB to RS-232 cable adapter
$19
$39
 

Configured model number

LTM600VF1

Configured price per model

$235

Quantity

1

Extended price

$235

 

 

  