Modbus & Serial Output Transmitter
for Process Signal Input

 Scalable for process signals requiring zero and span adjustment.
Ideal for pressure & flow. DIN Rail mounted, digitally programmable.

RoHS Mark

Made in California

Standard Features

  • 200 mV, 2V, 20V, 200V, 300V & 600V DC voltage ranges
  • 2, 20, 200 mA and 5A DC current ranges
  • All ranges factory calibrated
  • Digital span adjust from 0 to ±99,999
  • Digital zero adjust from -99,999 to +99,999
  • RS232 or RS485 serial communications, half or full duplex, isolated
  • Modbus RTU, Modbus ASCII or Laurel ASCII protocol
  • Output update rate to 60/sec
  • 4-20 mA, 0-20 mA or 0-10V transmitter output, jumper selectable, isolated
  • Easy setup with PC-based Instrument Setup Software
  • DIN rail mount housing only 22.5 mm wide
  • Detachable screw-clamp connectors
  • 5V, 10V or 24V dc transducer excitation output, isolated
  • Dual solid state relays for alarm or control, isolated
  • 0-10V, 4-20 mA or 0-20 mA analog output, scalable, isolated
  • Universal AC power, 85-264 Vac
  • Priced at only $235 (basic process transmitter)
    Options:
  • Extended main board for custom curve linearization & rate from successive readings
  • Low voltage power 10-48 Vdc or 12-32 Vac

Description

The Laureate Modbus & serial output, process signal input transmitter provides six DC voltage input ranges and four DC current input ranges for use with a wide range of transducers whose output requires zero and span adjustment. All ranges are factory calibrated and jumper selectable. The two most sensitive voltage ranges, 200 mV and 2V, provide a high input impedance of 1 Gohm to minimize the load on the voltage signal.

Fast read rate at up to 50 or 60 conversions per second while integrating the signal over a full power line cycle is provided by Concurrent Slope (Pat 5,262,780) analog-to-digital conversion. High read rate is ideal for peak or valley capture and for real-time computer interface and control. Digital signal filtering modes are selectable for stable readings in electrically noisy environments. The internal digital readings and analog output can be individually selected to be either unfiltered or filtered.

LTM Series serial output transmitters send data via an isolated serial port, which is user configurable for RS232 or RS485 and full or half duplex operation. Three protocols are user selectable: Modbus RTU, Modbus ASCII, or Laurel ASCII. Modbus operation is fully compliant with Modbus Over Serial Line Specification V1.0 (2002). The Laurel ASCII protocol allows up to 31 Laureate devices to be addressed on the same RS485 data line. It is simpler than the Modbus protocol and is recommended when all devices are Laureates. It also allows use of Laurel Datalogging Software.

Standard features of Laureate transmitters include:

  • Serial data output, isolated. User selectable RS232 or RS485, half or full duplex, Modbus or Laurel ASCII protocol.
  • Dual solid state relays for control or alarm, isolated. Rated 120 mA at 130 Vac or 170 Vdc.
  • Transducer excitation output, isolated. User selectable 5V@100 mA, 10V@120 mA or 24V@50 mA.
  • Analog transmitter output, 16-bit, user scalable and isolated. User selectable 4-20 mA, 0-20 mA or 0-10V levels.
  • Universal AC power supply for 85-264 Vac.

Easy Transmitter programming is via Laurel's Instrument Setup Software, which runs on a PC under MS Windows. This software can be downloaded from this website at no charge. The required transmitter-to-PC interface cable is available from Laurel (P/N CBL04).

Pinouts
Laureate Modbus & Serial Output Transmitter for Process Signal Input

Specifications
Laureate Modbus & Serial Output Transmitter for Process Signal Input

Analog Input

Range Input Ohms

Voltage
 
 
 
 

  200.00 mV 
2.0000 V
20.000 V
200.00 V
600.0 V
1 Gohm
1 Gohm
10 Mohm
10 Mohm
10 Mohm

Current
 
 
 

2.0000 mA
20.000 mA
200.00 mA
5.000 A
100 ohms
10 ohms
1 ohm
0.01 ohm

Input Resolution
Input Accuracy
Update Rate, Max
Max Applied Voltage
Current Protection

16 bits (65,536 steps)
±0.01% of full scale ± 2 counts
50/sec at 50 Hz, 60/sec at 60 Hz
600 Vac for 20, 200 & 600 V ranges, 125 Vac other ranges
25x for 2 mA, 8x for 20 mA, 2.5x for 200 mA, 1x for 5A

Transducer Excitation Output (standard)

Output Levels
Output Isolation

5V@100 mA, 10 @120 mA, 24V@50 mA (jumper selectable)
50V from signal ground

Serial Data Output (standard)

Signal Types
Data Rates
Output Isolation
Serial Protocols
Modbus Modes
Modbus Compliance
Digital Addressing

RS232 or RS485 (half or full duplex)
300, 600, 1200, 2400, 4800, 9600, 19200 baud
250V rms working, 2.3 kV rms per 1 min test
Modbus RTU, Modbus ASCII, Laurel ASCII
RTU or ASCII
Modbus over Serial Line Specification V1.0 (2002)
247 Modbus addresses.
Up to 32 devices on RS485 line w/o a repeater.

Dual Relay Output (standard)

Relay Type
Load Rating

Two solid state relays, SPST, normally open, Form A
130 mA at 140 Vac or 180 Vdc

Analog Output (standard)

Output Levels
Compliance, 4-20 mA
Compliance, 0-10V
Output Resolution
Output Accuracy
Output Isolation

4-20 mA, 0-20 mA, 0-10 Vdc (jumper selectable)
10V ( 0-500 ohm load )
2 mA ( 5 kOhm load or higher)
16 bits (65,536 steps)
0.02% of output span plus conversion accuracy
250V rms working, 2.3 kV rms per 1 minute test

Power Input

Standard Power
Low Power Option
Power Frequency
Power Isolation
Power Consumption

85-264 Vac or 90-300 Vdc (DC operation not UL approved)
10-48 Vdc or 12-32 Vac
DC or 47-63 Hz
250V rms working, 2.3 kV rms per 1 min test
2W typical, 3W with max excitation output

Mechanical

Dimensions
Mounting
Electrical Connections

120 x 101 x 22.5 mm
35 mm rail per DIN EN 50022
Detachable screw-clamp plugs

Environmental

Operating Temperature
Storage Temperature
Relative Humidity
Cooling Required

0°C to 55°C
-40°C to 85°C
95% at 40°C, non-condensing
Mount transmitters with ventilation holes at top and bottom.
Leave 6 mm (1/4") between transmitters, or force air with a fan.

Custom curve linearization

Using a linearizing digital panel meter or transmitter

A Laureate process meter or transmitter with the Extended main board option allows exceptionally accurate custom curve linearization. For setup, up to 180 data points can be entered into a spreadsheet. The system then creates multiple non-linear spline-fit segments, which provide much better accuracy than linear segments. One application, as illustrated, is the readout of volume of irregularly shaped tanks based on measured liquid level or pressure. Altimeters and thermistors are further applications.

Ordering Guide
Laureate Modbus & Serial Output Transmitter for Process Signal Input
 
Click on the radio buttons to build a model number with pricing (shown below the Ordering Guide).

  Quantity
Transmitter
Type
LTM   Laureate Transmitter, Modbus or Laurel ASCII Protocol $235
Main
Board
Standard Main Board
Extended Main Board
NC
$40

Note: Extended allows custom curve linearization and rate from successive readings.

Power 85-264 Vac
12-32 Vac or 10-48 Vdc
NC
$30
Relay
Output
None
Isolated Dual Solid State Relays
NC
NC
Analog Output None
4-20 mA, 0-10V
NC
NC
Signal
Input
Process Signals (e.g., 4-20 mA, 0-5 V)
P    Default Scaling. 4-20 mA in = 0-100.00 out
P1  Custom Scaling
 In the write-in field of your invoice, specify min input, min reading;
 max input, max reading.
 
NC

$10

Note: The same DC signal conditioner can be user configured for process, strain or potentiometer follower signals, as well as DC Volts or DC Amps. It is precalibrated in EEPROM for all DC Volt and DC Amp ranges listed for DC transmitters.

Accessories CBL04  RS-232 cable, LTM to computer or USB adapter
CBL02
  USB to RS-232 cable adapter
$19
$39
 

Configured model number

LTM2000P

Configured price per model

$235

Quantity

1

Extended price

$235

 

 

  

Products by Type

  

Meters by Application

  

Resource Pages