LTM-FR Modbus & Serial Output Transmitter
for Frequency, Rate or Period
 Dual channels. Rate and total in same transmitter.
DIN Rail mounted, digitally programmable.

Standard Features

  • Selectable Modbus or Laurel ASCII protocol.
  • Modbus RTU or ASCII modes, 2-wire connection, up to 247 digital addresses.
  • Two independently field-scalable pulse input channels.
  • Frequencies from 0.005 Hz to 1 MHz.
  • Inputs from NPN or PNP proximity switches, contact closures, digital logic, magnetic pickups down to 12 mV, or AC inputs up to 250 Vac.
  • Input signal scaled to six-digit readings:
    - Digital span adjust from 0 to ±999,999.
    - Digital zero adjust from -999,999 to +999,999.
  • Selectable "count by" of 10 or 100 with rounding.
  • Line frequency measurement to 60.0000 in a few line cycles.
  • Square root extraction standard.
  • DIN rail mount package only 22.5 mm thick.
  • 5V, 10V or 24V dc sensor excitation output, isolated.
  • Dual solid state relays for alarm or control, isolated.
  • 0-10V, 4-20 mA  or 0-20 mA  transmitter output, isolated.
  • Universal AC power, 95-240 Vac ±10%
  • Priced at only $235 (basic pulse input transmitter)
    Options:
  • Extended Main Board for rate and total simultaneously, custom curve linearization, arithmetic functions A+B, A-B, AxB, A/B, A/B-1 (draw).
  • Low voltage power, 10-48 Vdc or 12-30 Vac.
Serial ASCII or Modbus Transmitter, Frequency, Rate or Period Input

CE Mark       RoHS Mark

Description

The Laureate LTM-FR serial output, frequency, rate and period input transmitter accepts two independently scalable input channels from a wide range of pulse sources, such as NPN or PNP proximity switches, contact closures, digital logic, magnetic pickups down to 12 mV, or AC voltages to 250 Vac. Input frequencies can range from 0.005 Hz to 1 MHz. Applications include AC line frequency, RPM or speed from proximity switch inputs, and flow from turbine flow meter inputs.

  • With a Standard Main Board, the transmitter output can be scaled to track frequency in Hz, rate (such as gallons per minute), or period (inverse of frequency). Square root extraction is standard.
       
  • With an Extended Main Board, the transmitter output can track rate or totalized rate (such as gallons) whether the transducer output is linear, requires square root extraction, or requires custom curve linearization. The latter can be provided by a curvilinear spline fit with up to 180 data points. The transmitter can also count up to a preset total or down from a preset total to zero. Such applications typically make use of optional dual solid state relays, which are available as options. External reset of totals is via a special three-position screw terminal connector. The two input channels A & B can also be combined arithmetically to provide an analog transmitter output that tracks A+B (e.g., sum of two flows), A-B (e.g., difference of two flows), AxB (e.g., horsepower as product of force and RPM), A/B (ratio of two flow), and A/B-1 (draw or relative elongation of material between rollers).

Signal conditioner board used with 4-20 mA current transmitter for frequency, rate or periodExceptional Accuracy and Stability. Laureate pulse input frequency and rate transmitters determine frequency by taking the inverse of period as measured with a calibrated quartz crystal time base. This results in extremely accurate and stable 6-digit readings (±999,999 counts), which are then scaled in software. The update rate of the transmitter output is a programmed gate time + 30 ms + 0-2 signal periods. For a 60 Hz signal, the update rate would be 20 per second. Such fast update rates are ideal for alarm and control.

LTM Series serial output transmitters send data via an isolated serial port, which is user configurable for RS232 or RS485 and full or half duplex operation. Three protocols are user selectable: Modbus RTU, Modbus ASCII, or Laurel ASCII. Modbus operation is fully compliant with Modbus Over Serial Line Specification V1.0 (2002). The Laurel ASCII protocol allows up to 31 Laureate devices to be addressed on the same RS485 data line. It is simpler than the Modbus protocol and is recommended when all devices are Laureates. It also allows use of Laurel Datalogging Software.

Standard features of Model LTM-FR include:

  • Serial data output, isolated. User selectable RS232 or RS485, half or full duplex, Modbus or Laurel ASCII protocol.
  • Dual solid state relays for control or alarm, isolated. Rated 120 mA at 130 Vac or 170 Vdc.
  • Transducer excitation output, isolated. User selectable 5V@100 mA, 10V@120 mA or 24V@50 mA.
  • Analog transmitter output, 16-bit, user scalable and isolated. User selectable 4-20 mA, 0-20 mA or 0-10V levels.
  • Universal AC power supply for 95-240 Vac ±10%.

Easy Transmitter programming is via Laurel's Instrument Setup Software, which runs on a PC under MS Windows. This software can be downloaded from this website at no charge. The required transmitter-to-PC interface cable is available from Laurel (P/N CBL04).

Specifications
LTM-FR Modbus & Serial I/O Transmitter for Frequency, Rate or Period

Pulse Input
Types

Ch A Frequency, Max
Ch B Frequency, Max
Signal Ground
Minimum Signal
Maximum Signal
Maximum Frequency
Contact Debounce
Time Base Accuracy
Span Tempco
Long-term Drift
AC, pulses from NPN, PNP transistors, contact closures,
magnetic pickups.
1 MHz
250 kHz
Common ground for channels A & B
Nine ranges from (-12 to +12 mV) to (+1.25 to +2.1V)
250 Vac
1 MHz, 30 kHz,  250 Hz (selectable)
0, 3, 50 ms (selectable)
Quartz crystal calibrated to ±2 ppm
±1 ppm/°C (typ)
±5 ppm/year
Serial Data Output (standard)
Signal levels
Data Rates
Output Isolation
Serial Protocols
Devices on RS-485 Line
Modbus Addresses
Modbus Modes
Modbus Compliance
RS232 or RS485 (half duplex)
300, 600, 1200, 2400, 4800, 9600, 19200 baud
250V rms working, 2.3 kV rms per 1 min test
Modbus RTU, Modbus ASCII, Laurel ASCII (selectable)
32 max without a repeater.
247 max
RTU or ASCII, 2-wire.
Modbus over Serial Line Specification V1.0 (2002)
Dual Relay Output (standard)
Relay Type
Load rating
Two solid state relays, SPST, normally open, Form A
120 mA at 130 Vac or 170 Vdc, 28 ohms in series
Transducer Excitation Output (standard)
Output levels
Output isolation
5V@100 mA, 10V@120 mA, 24V@50 mA (jumper selectable)
50V from signal ground
Analog Output (standard)
Output Levels
Compliance, 4-20 mA
Compliance, 0-10V
Output Resolution
Output Accuracy
Output Isolation
4-20 mA, 0-20 mA, 0-10 Vdc (jumper selectable)
10V ( 0-500 ohm load )
2 mA ( 5 kOhm load or higher)
16 bit DAC
±0.02% of output span plus conversion accuracy
250V rms working, 2.3 kV rms per 1 minute test
Power Input
Standard power
Low power option
Frequency
Power Isolation
95-240 Vac ±10% or 90-300 Vdc (DC operation not UL approved)
12-30 Vac or 10-48 Vdc
DC or 47-63 Hz
250V rms working, 2.3 kV rms per 1 min test
Mechanical
Case Dimensions
Case Mounting
Electrical Connections
120 x 101 x 22.5 mm
35 mm rail per DIN EN 50022
Detachable screw clamp plug connectors
Environmental
Operating Temperature
Storage Temperature
Relative Humidity
0°C to 70°C
-40°C to 85°C
95% at 40°C, non-condensing

Application Examples

AC Line Frequency

AC Line Frequency Meter or Transmitter The Laureate will accept line voltages up to 250 Vac and display line frequency to 6-digit accuracy (50.0000 or 60.0000) in a few line cycles. Fast low frequency response is achieved by timing the period and taking its inverse.

RPM and Speed

Tachometer and Pulse Input Rate Meter or Transmitter The Laureate can sense the low-level signals from magnetic pickups or the NPN or PNP transistor output of active sensors. These can be powered directly by the meter. Display in RPM or units of speed is achieved by mathematically scaling the meter.

Flow Rate and Simultaneous Total

Simultaneous Rate Meter or Transmitter and Totalizer The Laureate is compatible with all flow meters which generate pulses at a frequency proportional to flow rate. The Extended version can display scaled rate or total for the same input at the push of a button, and alarm from both the rate and total. The Extended version can also linearize flow transducers so as to extend their dynamic range.

Combining Two Rates

Dual Pulse Input Rate Meter or Transmitter to Combine Two Rates The Extended Laureate offers A+B, A-B and A/B arithmetic functions. A+B allows two input flows to be summed for total flow, while A-B allows outflow to be subtracted from inflow for net flow. Flow ratios aid in the proper mixing of ingredients

Custom Curve Linearization

Custom Curve Linearization for Laureate Rate Meters or Transmitters The Extended Laureate can linearize the output turbine flow meters, which tend to be nonlinear on the low end. Linearizing improves the dynamic range and accuracy of turbine flow meters.

System-level Capabilities

The Laureate dual channel rate meter can independently scale, display and alarm two pulse input channels. All signal or alarm data can further be transmitted via RS-232 or RS-485, including peak readings and arithmetic combinations of the two rates. The displayed rates can also be transmitted as isolated isolated 4-20 mA or 0-10V analog output.

System Interfaces of Laureate Frequency / Rate Transmitters

Pinout
LTM-FR Modbus & Serial I/O Transmitter for Frequency, Rate or Period

Ordering Guide
LTM-FR Modbus & Serial I/O Transmitter
for Frequency, Rate or Period

 Click on the radio buttons to build a model number with pricing.

  Quantity
Transmitter
Type
LTM    Laureate Transmitter, Modbus or Laurel ASCII Protocol $235
Main Board Standard Main Board
Extended Main Board
Note:
Extended allows custom curve linearization and rate from successive readings.
NC
$40
Power Isolated 95-240 Vac ±10%
Isolated 12-30 Vac or 10-48 Vdc
NC
$30
Setpoint
Output
None
Isolated Dual Solid State Relays
NC
NC
Analog Output None
Isolated 4-20 mA, 0-20 mA or 0-10V Analog Output
NC
NC
Input Type FR  Dual-Channel Frequency  NC
Accessories CBL04  RS-232 cable, LTM to computer or USB adapter
CBL02  USB to RS-232 cable adapter
$19
$39
 
Configured model number LTM6000FR
Configured price per model $235
Quantity 1
Extended price $235
 

 