LTA-VF 4-20 mA Current Transmitter &
Totalizer for 0-1 mA, 4-20 mA or 0-10V

 Scalable to flow rate or total flow from process signals.
DIN Rail mounted, digitally programmable.

Standard Features

  • Isolated 4-20 mA or 0-10V transmitter output, selectable.
  • Output tracks rate or total.
  • 0-1 mA, 4-20 mA or 0-10V process signal input.
  • Output accuracy maintained for narrow or wide spans.
  • Selectable square root for differential flow.
  • Output resolution:  0.0015% of span (16 bits).
  • Output accuracy: ±0.02% of span.
  • Output update rate: 25/sec.
  • DIN rail mount package only 22.5 mm thick.
  • Detachable screw clamp plug connectors.
  • Easy setup with PC-based Instrument Setup Software.
  • 5V, 10V or 24V dc sensor excitation output, isolated.
  • Dual solid state relays for alarm or control, isolated.
  • RS232 or RS485 serial communications, isolated.
  • Universal AC power, 95-240 Vac ±10%
  • Priced at only $235 (basic totalizer transmitter)
    Options:
  • Extended Main Board for custom curve linearization,
    time based on rate (1/rate).
  • Low voltage power, 10-48 Vdc or 12-30 Vac.
4-20 mA Current Transmitter and Totalizer for 0-1 mA, 4-20 mA and 0-10V Signals

CE Mark       RoHS Mark

Description

The Laureate LTA-VF process signal input totalizing transmitter accepts 0-1 mA, 4-20 mA or 0-10V signals from flow meters and other transducers, such as watt meters, to track rate or totalized rate.

  • With a Standard Main Board, the transmitter output can track rate (such as gallons per minute or watts) or totalized rate (such as gallons or kilowatt hours) whether the transducer output is linear or requires square root extraction (differential pressure flow transducers).
      

  • With an Extended Main Board, the transmitter can also perform custom curve linearization (provided by a curvilinear spline fit with up to 180 data points), display 1/ rate (such as the time it takes a conveyor to pass through an oven), and perform batch control for repetitive fill operations.  Such applications typically make use of optional dual solid state relays, which are available as options. External reset of totals is provided by a special connector.

Signal Conditioner Board for Laureate Analog Input Flow Rate Meter and Analog Flow TotalizerThe V-to-F signal conditioner board converts the full-scale 0-1 mA, 4-20 mA or 0-10 V analog signal to a frequency of 10 kHz to 110 kHz. This frequency is determined by measuring period over a selected gate time (from 10 ms to 200 s) and taking the inverse of period. At the lowest frequency of 10 kHz and the minimum gate time of 10 ms, the transmitter is capable of 25 updates per second. Scaling is done mathematically. Totals are stored in nonvolatile memory in case of power loss.

Three analog transmitter settings are jumper selectable: 4-20 mA, 0-20 mA or 0-10V. All selections provide 16-bit (0.0015%) resolution of output span and 0.02% output accuracy. The output tracks the reading from -99,999 to +99,999 counts that would be transmitted digitally. For process signals, this reading has a rated accuracy of ±0.01% of full scale input and can be scaled in software. Output isolation from signal and power grounds eliminates potential ground loop problems. The supply can drive 20 mA into a 500 ohm (or lower) load for 10V compliance, or 10V into a 5K ohm (or higher) load for 2 mA compliance.

Standard features of Model LTA-VF include:

  • Analog transmitter output, 16-bit, user scalable and isolated. User selectable 4-20 mA, 0-20 mA or 0-10V levels.
  • Serial communications, isolated. User selectable RS232 or RS485, half or full duplex, Modbus or Laurel ASCII protocol.
  • Dual solid state relays for control or alarm, isolated. Rated 120 mA at 130 Vac or 170 Vdc.
  • Transducer excitation output, isolated. User selectable 5V@100 mA, 10V@120 mA or 24V@50 mA.
  • Universal AC power supply for 95-240 Vac ±10%.

Easy Transmitter programming is via Laurel's Instrument Setup Software, which runs on a PC under MS Windows. This software can be downloaded from this website at no charge. The required transmitter-to-PC interface cable is available from Laurel (P/N CBL04).

Specifications
LTA-VF 4-20 mA Transmitter & Totalizer
for 0-1 mA, 4-20 mA or 0-10V Signals

Analog Input 0-1 mA 4-20 mA 0-10 V
Input resistance
Max current or voltage
182 ohms
37 mA
9 ohms
160 mA
1 Mohm
600 V
Input Resolution
Span Tempco
Zero Tempco
Accuracy at 25°C

Read Rate

6 digits
±0.0025% R/°C
±0.0005 FS/°C
±0.005% FS ±1 count
25/sec (typical)

Analog Output
Output Levels
Compliance, 4-20 mA
Compliance, 0-10V
Output Resolution
Output Accuracy
Output Update Rate
Output Isolation
4-20 mA and  0-10 Vdc (selectable)
10V ( 0-500 ohm load )
2 mA ( 5 kOhm load )
12 bits (4,096 steps)
±0.05% of output span
25/sec
250V rms working, 2.3 kV rms per 1 minute test
Transducer Excitation Output (standard)
Jumper Selection 1
Jumper Selection 2
Jumper Selection 3
10V @ 60 mA, isolated to 50V from signal ground
5V @ 50 mA, isolated to 50V from signal ground
15V @ 60 mA, non-isolated
Dual Relay Output (optional)
Relay Type
Load rating
Two solid state relays, SPST, normally open, Form A
120 mA at 130 Vac or 170 Vdc, 28 ohms in series
Power Input
Standard power
Low power option
Frequency
Power Isolation
95-240 Vac ±10% or 90-300 Vdc (DC operation not UL approved)
12-30 Vac or 10-48 Vdc
DC or 47-63 Hz
250V rms working, 2.3 kV rms per 1 min test
Mechanical
Case Dimensions
Case Mounting
Electrical Connections
120 x 101 x 22.5 mm
35 mm rail per DIN EN 50022
Detachable screw clamp plug connectors
Environmental
Operating Temperature
Storage Temperature
Relative Humidity
0°C to 70°C
-40°C to 85°C
95% at 40°C, non-condensing

Pinout
LTA-VF 4-20 mA Transmitter & Totalizer
for 0-1 mA, 4-20 mA or 0-10V Signals

Ordering Guide
LTA-VF 4-20 mA Transmitter & Totalizer
for 0-1 mA, 4-20 mA or 0-10V Signals

 Click on the radio buttons to build a model number with pricing.

  Quantity
Transmitter
Type
TA    Laureate 4-20 mA Transmitter $235
Main Board Standard Main Board
Extended Main Board
NC
$40
With Standard Main Board: Rate, square root of rate, or totalized rate from differential pressure flow transducers with a DC output.
With Extended Main Board:
Above plus linearization of nonlinear inputs, batch operation, 1/rate (time).
Power Isolated 95-240 Vac ±10%
Isolated 12-30 Vac or 10-48 Vdc
NC
$30
Setpoint
Output
None
Isolated Dual Solid State Relays
NC
NC
Input Type Voltage-to-Frequency Converter
VF1  V-to-F Converter, 4-20 mA
VF2  V-to-F Converter, 0-1 mA
VF3  V-to-F Converter, 0-10V
In the write-in field of your invoice, specify min input, min reading; max input, max reading.
 
NC
Accessories CBL04  RS-232 cable, LTA to computer or USB adapter
CBL02    USB to RS-232 cable adapter
$19
$39
 
Configured model number LTA600VF1
Configured price per model $235
Quantity 1
Extended price $235
 

 