4-20 mA Current Output Transmitter
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
Standard Features
|
![]()
Description The Laureate 4-20 mA output, pulse input totalizer transmitter accepts two independently scalable input channels from a wide range of pulse sources, such as NPN or PNP proximity switches, contact closures, digital logic, magnetic pickups down to 12 mV, or AC voltages to 250 Vac. Input pulse rates can be as high as 1 MHz.
Standard features of Laureate transmitters include:
Easy Transmitter programming is via Laurel's Instrument Setup Software, which runs on a PC under MS Windows. This software can be downloaded from this website at no charge. The required transmitter-to-PC interface cable is available from Laurel (P/N CBL04). |
![]()
Specifications
Laureate 4-20 mA Transmitter &
|
Pulse Input |
|
|
Types |
AC,
pulses from NPN, PNP transistors, contact closures, |
|
Analog Output |
|
|
Output Levels |
4-20 mA and 0-10 Vdc (selectable) |
|
Transducer Excitation Output (standard) |
|
|
Jumper Selection 1 |
10V @ 60 mA, isolated to 50V from signal ground |
|
Dual Relay Output (optional) |
|
|
Relay Type |
Two solid state relays, SPST, normally open,
Form A |
|
Power Input |
|
|
Standard Power |
85-264 Vac or 90-300 Vdc (DC operation not UL approved) |
|
Mechanical |
|
|
Dimensions |
120 x 101 x 22.5 mm |
|
Environmental |
|
|
Operating
Temperature |
0°C
to 55°C |
![]()
| Application Examples of Totalizing Meters | |
Up/Down Totalizing |
|
![]() |
Up/down totalizing is provided by a mode of the Extended totalizing transmitter where pulses are either added or subtracted on Channel A based on a direction input on Channel B. The unit can also be programmed so that counting by Channel A is inhibited by an input on Channel B. |
Combining Two Totals |
|
![]() |
A+B, A-B, A/B and AxB arithmetic functions are available with the Extended totalizing transmitter. A+B can sum two totals, while A-B subtracts the outflow total from inflow total. A/B ratio applied to two totals helps assure the proper mixing of components. |
Up or Down Counting with Preset |
|
![]() |
A single Laureate dual-channel totalizing transmitter will handle two repetitive fill operations by counting from zero up to a preset, or down from a preset to zero. The dual relay option is required. |
Machine ON Time and Utilization |
|
![]() |
An easy way to measure the ON time of machines is to count AC line cycles and scale the total to hours. To display machine utilization or duty cycle in percent, use the Extended totalizing transmitter. Connect Channel A to switched AC and Channel B to the AC line, and apply a 100 multiplier to the A/B ratio. |
Total and Rate Simultaneously |
|
|
|
The Extended version of the Laureate dual channel totalizing transmitter can transmit scaled rate or total for the same channel at the push of a button, and alarm both the rate and total. The Extended version can also do curve linearization, thereby extending the working range and accuracy of flow transducers. |
![]()
Pinout
Laureate 4-20 mA Transmitter & Dual Pulse
Input Totalizer

![]()
Ordering
Guide
Laureate 4-20 mA Transmitter & Dual Pulse
Input Totalizer
Click on the radio buttons to build a model number with pricing (shown below the Ordering Guide).
|