Laureate™ Thermocouple & RTD
Temperature Panel Meter / Controllers

High accuracy plus linearized transmitter & control outputs
  

Laurel Thermocouple & RTD Temperature Meter
CE Mark   UL Mark RoHS Mark

Features

  • Input for thermocouple types J, K, T, E, N, R, S.
  • Input for 100 ohm platinum RTDs with DIN and ANSI curves.
  • High accuracy & repeatability.
  • Celsius, Fahrenheit, Kelvin or Rankine scales.
  • Selectable 1º or 0.1º resolution.
  • 2, 3 or 4-wire RTD connection with lead resistance compensation.
  • Upscale or downscale open sensor indication.
  • Up to 60 conversions per second.
  • Peak value display.
  • AC or DC powered.
  • Green or red display.
  • NEMA 4X, 1/8 DIN case.
  • Dual relay option.
  • Analog output option.
  • Serial communication options.
  • Low voltage AC & DC power.
  • Certified to UL 61010C-1 (UL mark), EN 61010-1 (CE mark), and RoHS.

Description

Laurel digital panel meter for thermocouple or RTD input

Laureate™ digital panel meters with the temperature signal conditioner board provide highly accurate, stable and repeatable temperature indication for multiple thermocouple types and 100 Ohm platinum RTDs. The meter accepts the outputs of types J, K, T, E, N, R and S thermocouples, plus 100 ohm platinum RTD’s with DIN alpha of 0.00385 and ANSI alpha of 0.003925. The thermocouple or RTD type, unit of measure (°C or °F), resolution (1° or 0.1°), and range are selectable from the front panel or via the serial interface. Display in Kelvin or Rankine can be selected by offsetting the Celsius or Fahrenheit range.

Cold junction compensation automatically corrects for temperature variations at the thermocouple reference junction at the meter. Open sensor indication is standard and may be set up to indicate either upscale or downscale. RTD excitation is provided by the meter. RTD connections can be of the 2-, 3- or 4-wire type. For 3- and 4-wire connections, the meter automatically compensates for lead resistance of the sensor.

Signal conditioner for Laureate Thermocouple & RTD Temperature MeterAll ranges for all temperature sensor types are digitally calibrated at the factory. This eliminates the need for field calibration or drift caused by potentiometers found in non-microcomputer based meters.

All Laureate meters allow exceptionally fast read rates. Concurrent Slope (Pat 5,262,780) is a method of analog-to-digital conversion that allows up to 60 conversions per second while integrating the input over a full power cycle. Fast read rates provide true readings and fast response for control applications. Display of peak value is standard.

Plug-in isolated analog output, dual-setpoint controller, and RS-232/485 communications boards can upgrade the Laureate from stand-alone monitor to system interface and control. The Laureate temperature meter can serve as a highly accurate, isolated, 4-20 mA transmitter.

Laureate panel meters are available with a red or green LED display. Blanking of leading, non-significant zeros simplifies reading. The 1/8 DIN case is water tight to NEMA 4X (IP-65) from the front when panel mounted.

Specifications

Thermocouple Input
  
TC Type Range Error at 25°C
.01% FS
J -210°C to +760°C
-347°F to +1400°F
±0.09°C
±0.16°F
K -244°C to +1372°C
-408°F to +2501°F
±0.1°C
±0.17°F
T 0°C to +400°C
-257°C to 0°C
+32°F to 752°F
-430°F to +32°F
±0.03°C
±0.2°C
±0.05°F
±0.36°F
E -240°C to +1000°C
-400°F to +1830°F
±0.18°C
±0.32°F
N -245°C to +1300°C
-410°F to +2370°F
±0.10°C
±0.17°F
R -45°C to +1768°C
-49°F to +3214°F
±0.17°C
±0.31°F
S -46°C to +1768°C
-51°F to +3213°F
±0.12°C
±0.22°F
  

Applicable to all thermocouple types

Calibration
Input resistance
Input current
Max lead resistance
Overall accuracy
Span tempco
Reference junction accuracy
Span tempco
Overvoltage protection

NMR at 50/60 Hz
 
CMR, DC-60 Hz
CMV, DC-60 Hz
Open sensor indication

NIST Monograph 125 (IPTS-68)
1 Gohm
100 pA
1 kohm max for rated accuracy
±0.01% of full span ±2 counts
±0.003% of reading/ºC
1ºC, 10ºC to 40ºC
±0.003% of reading/ºC
125 Vac
80 dB plus selectable digital filter
from 80 ms to 9.6 s time constant.
120 dB with 500 W imbalance
250 Vac from power and earth grounds.
Flashes full-scale.

Pt 100 RTD Input

RTD Alpha Range Error at 25°C
.01% FS
DIN
.00385
-202°C to +850°C
-331°F to +1562°F
±0.03°C
±0.05°F
ANSI
.003925
-202°C to +631°C
-331°F to +1168°F
±0.04°C
±0.07°F
   

Applicable to all RTD types

Calibration, DIN
Calibration ANSI

Configuration
Excitation current
Overall accuracy
Span tempco
Zero tempco
Overvoltage protection
Open sensor indication
IEC 751 (IPTS-68)
NIST Monograph 126
2, 3 or 4-wire connection
0.2 mA
±0.01% of full span ±2 counts
±0.003% of reading/ºC
±0.03 deg/deg
125 Vac
Flashes full-scale
Sensor lead resistance tempco per conductor 2-wire, 10 mdeg/W/deg up to 10 W
3 & 4-wire, 10 mdeg/W/deg up to 100 W

Thermocouple & RTD

Display
Readout
Color
Indicators
5 digits, 7-segment, 14.2 mm (.56")
Red or green LED
Minus sign, 2 red LED lamps
A-to-D Conversion
Technique
A-to-D Rate
Output Update
Display Update
Concurrent Slope(Pat 5,262,780)
60/s at 60 Hz, 50/s at 50 Hz
56/s at 60 Hz, 47/s at 50 Hz
3.5/s at 60 Hz, 3/s at 50 Hz
Power
Voltage, standard
Voltage, optional
Frequency
Power Isolation
95-240 Vac ±10% or 90-300 Vdc (DC operation not UL approved)
12-30 Vac or 10-48 Vdc
DC or 47-63 Hz
250V rms working, 2.3 kV rms per 1 min test
Analog Output (optional)
Output levels
Compliance
Scaling
Resolution
Isolation
0-10V, 0-20 mA, 4-20 mA (jumper selectable)
2 mA at 10V ( > 5 kOhm), 12V at 20 mA ( < 60 ohms)
Zero and full scale adjustable from -99999 to +99999
12 bits (0.025% of full scale)
250V rms working, 2.3 kV rms per 1 min test
Dual Contact Relay Outputs (optional)
Relay Type
Load Rating
Isolation
Form C
8A at 250 Vac or 24 Vdc
250V rms working, 2.3 kV rms per 1 min test
Dual Solid State Relay Outputs (optional)
Relay Type
Load Rating
Isolation
SPST, normally open, Form A
120 mA at 130 Vac or 170 Vdc, 28 ohms in series
250V rms working, 2.3 kV rms per 1 min test
Serial Data I/O (optional)
Board Selections
Protocols
Data Rates
Digital Addresses
Isolation
RS232, RS485, Modbus RS485
Modbus RTU, Modbus ASCII, simpler Laurel ASCII
300 to 19200 bps
247 (Modbus), 31 (Laurel ASCII),
250V rms working, 2.3 kV rms per 1 min test
Environmental
Operating Temp.
Storage Temp.
Relative Humidity
Protection
0°C to 60°C
-40°C to 85°C
95% at 40°C, non-condensing
NEMA-4X (IP-65) when panel mounted

RTD Connections with Excitation & Lead Compensation

2-wire RTD connection to Laureate temperature panel meter

The Laureate temperature meter allows 2-, 3- and 4-wire RTD hookup to the J5 connector. The meter applies an excitation current of 0.2 mA, which it monitors to make ratiometric corrections for excitation supply variations.

In 2-wire hookup, the meter senses the voltage drop across the 100 ohm RTD and both lead wires. The effect of the lead wires can be measured and subtracted by shorting out the RTD during meter setup.

In 3- and 4-wire hookup, the meter senses the voltage drop across the 100 ohm RTD and both lead wires as well as the voltage drop across the RTD and one lead wire. This allows the meter to determine the effect of one lead wire and mathematically subtract the effect of both lead wires.

3-wire RTD connection to Laureate temperature panel meter

4-wire RTD connection to Laureate temperature panel meter

Application Examples

Linearized 4-20 mA transmitter output of Laureate temperature panel meter

Operation as a 4-20 mA Transmitter

With the optional analog output board, Laureate temperature meters can serve as superb, isolated 4-20 mA transmitters. The analog output is scaled to the display, which is linearized to ºC or ºF and is exceptionally accurate. The analog output further tracks the high read rate of the meter, at up to 60 readings per second at 60 Hz power. Fast update rates are beneficial in many closed-loop and PID control applications.

Temperature controller operation of Laureate temperature panel meter Combined temperature controller and 4-20 mA transmitter operation of Laureate temperature panel meter

Operation as a Fast Controller

With the dual contact relay or dual solid state relay output board options, Laureate temperature meters can serve as extremely fast and accurate ON/OFF controllers for closed-loop temperature control.

Multiple setpoint operating modes are individually selectable for each relay, as explained in the dual-setpoint controller section. Relay duty cycles and chatter can be minimized with programmable hysteresis and time delays. High duty cycles and extremely fast response times are possible with the solid state relay, which has a typical response time of only 17 ms.

Operation as a Supervisory Monitor

By using the optional dual contact relay or dual solid state relay output options, Laureate temperature meters can monitor processes and provide alarms or shutoffs when these processes exceed normal limits.

A band deviation operating mode can be selected for each relay, where an alarm is generated whenever the reading is a selected number of counts above or below the setpoint. Relay operation can be selected as latching or non-latching. When an alarm or shutdown condition is reached, a latched output will remain in the alarm condition until it is reset by a front panel pushbutton, via the serial interface, or via the rear connector.

Ordering Guide
Laureate™ Thermocouple & RTD Temperature Panel Meters
 Click on the radio buttons to build a model number with pricing.

Quantity

DPM
Type
L    Digital Panel Meter. $220
Main
Board
Standard Main Board, Green LEDs.
Standard Main Board, Red LEDs.
NC
NC
Power Isolated 95-240 Vac ±10%
Isolated 12-30 Vac & 10-48 Vdc.
NC
$30
Setpoint
Output
None.
Dual 8A Contact Relays.
Isolated Dual Solid State Relays.
NC
$80

$55
Analog
Output
None.
Isolated 0-20 mA & 0-10 V.
NC
$90
Digital
Interface
None.
Isolated RS-232.
Isolated RS-485.
Isolated Modbus RS-485.
NC
$60

$80

$90
Signal
Input
Thermocouples
JC  Thermocouple Type J, -210°C to 760°C.
JF  Thermocouple Type J, -347°F to 1400°F.
KC  Thermocouple Type K, -347°C to 1372°C.
KF  Thermocouple Type K, -408°F to 2501°F.
TC  Thermocouple Type T, -257°C to 400°C.
TF  Thermocouple Type T, -430°F to 752°F.
EC  Thermocouple Type E, -240°C to 1000°C.
EF  Thermocouple Type E, -400°F to 1830°F.
NC  Thermocouple Type N, -240°C to 1000°C.
NF  Thermocouple Type N, -410°F to 2370°F.
SC  Thermocouple Type S, -46°C to 1768°C.
SF  Thermocouple Type S, -51°F to 3214°F.
RC  Thermocouple Type R, -45°C to 1768°C.
RF  Thermocouple Type R, -49°F to 3213°F.
 
NC
RTDs (100 Ohm Platinum)
P385C  RTD Alpha .00385, -202°C to 850°C.
P385F  RTD Alpha .00385, -331°F to 1562°F.
P392C  RTD Alpha .003925, -202°C to 631°C.
P392F  RTD Alpha .003925, -331°F to 1168°F.
 
NC
Note: The same temperature signal conditioner board can be user configured for all thermocouple and RTD types listed. Temperatures for each type are spanned by a single range.  
Add-on
Options
EB  Extra bight red LED display
BL 
Blank lens without button pads
CBL01  RJ11-to-DB9 cable
CBL02
  USB-to-DB9 adapter
IPC  Clear front panel cover sealed to NEMA 4X / IP65
BOX1 
NEMA-4X wall-mount enclosure with 1/8 DIN cutout
BOX2 
NEMA-4X enclosure with 1/8 DIN cutout plus IPC
$30
NC

$19

$39

$40

$140

$180
 
Configured model number L10000JC
Configured price per model $220
Quantity 1
Extended price $220
 

 