Laureate™ Thermocouple & RTD
Temperature Panel Meter / Controllers
High accuracy plus linearized transmitter
& control outputs

Features
- Input for thermocouple types J, K, T, E, N, R, S.
- Input for 100 ohm platinum RTDs
with DIN and ANSI curves.
- High accuracy &
repeatability.
- Celsius, Fahrenheit, Kelvin or
Rankine scales.
- Selectable 1º or
0.1º resolution.
- 2, 3 or 4-wire RTD connection
with lead resistance compensation.
- Upscale or downscale open sensor
indication.
- Up to 60 conversions per second.
- Peak value display.
- AC or DC powered.
- Green or red display.
-
NEMA 4X, 1/8 DIN case.
-
Dual relay option.
-
Analog output option.
-
Serial communication options.
- Low voltage AC & DC power.
- Certified to UL 61010C-1 (UL mark), EN 61010-1 (CE mark),
and RoHS.
|

Description

Laureate
digital panel meters with the temperature signal conditioner board provide highly accurate, stable
and repeatable temperature indication for multiple thermocouple types and 100 Ohm platinum
RTDs. The meter accepts the outputs of types J, K, T, E, N, R and S thermocouples, plus
100 ohm platinum RTDs with DIN alpha of 0.00385 and ANSI alpha of 0.003925. The
thermocouple or RTD type, unit of measure (°C or °F), resolution (1° or 0.1°),
and range are selectable from the
front panel or via the serial interface. Display in Kelvin or Rankine can be selected by
offsetting the Celsius or Fahrenheit range.
Cold junction compensation automatically
corrects for temperature variations at the thermocouple reference junction at the meter.
Open sensor indication is standard and may be set up to indicate either upscale or
downscale. RTD excitation is provided by the meter. RTD connections can be of the 2-, 3-
or 4-wire type. For 3- and 4-wire connections, the meter automatically compensates for
lead resistance of the sensor.
All ranges for all temperature sensor types
are digitally calibrated at the factory. This eliminates the need for field calibration or
drift caused by potentiometers found in non-microcomputer based meters.
All Laureate meters allow exceptionally fast
read rates. Concurrent Slope (Pat 5,262,780) is a method of analog-to-digital conversion
that allows up to 60 conversions per second while integrating the input over a full power
cycle. Fast read rates provide true readings and fast response for control applications.
Display of peak value is standard.
Plug-in isolated
analog output, dual-setpoint controller,
and
RS-232/485 communications boards can upgrade the Laureate from stand-alone
monitor to system interface and control. The Laureate temperature meter
can serve as a highly accurate, isolated, 4-20 mA transmitter.
Laureate panel meters are available with
a red or green LED display. Blanking of leading, non-significant zeros
simplifies reading. The 1/8 DIN case is
water tight to NEMA 4X (IP-65) from the front when panel mounted.
|

Specifications
Thermocouple Input
| TC Type |
Range |
Error at 25°C
.01% FS |
| J |
-210°C to
+760°C
-347°F to +1400°F |
±0.09°C
±0.16°F |
| K |
-244°C to
+1372°C
-408°F to +2501°F |
±0.1°C
±0.17°F |
| T |
0°C to
+400°C
-257°C to 0°C
+32°F to 752°F
-430°F to +32°F |
±0.03°C
±0.2°C
±0.05°F
±0.36°F |
| E |
-240°C to
+1000°C
-400°F to +1830°F |
±0.18°C
±0.32°F |
| N |
-245°C to
+1300°C
-410°F to +2370°F |
±0.10°C
±0.17°F |
| R |
-45°C to
+1768°C
-49°F to +3214°F |
±0.17°C
±0.31°F |
| S |
-46°C to
+1768°C
-51°F to +3213°F |
±0.12°C
±0.22°F |
Applicable
to all thermocouple types |
Calibration
Input resistance
Input current
Max lead resistance
Overall accuracy
Span tempco
Reference junction accuracy
Span tempco
Overvoltage protection
NMR at 50/60 Hz
CMR, DC-60 Hz
CMV, DC-60 Hz
Open sensor indication |
NIST
Monograph 125 (IPTS-68)
1 Gohm
100 pA
1 kohm max for rated accuracy
±0.01% of full span ±2 counts
±0.003% of reading/ºC
1ºC, 10ºC to 40ºC
±0.003% of reading/ºC
125 Vac
80 dB plus selectable digital filter
from 80 ms
to 9.6 s time constant.
120 dB with 500 W imbalance
250 Vac from power and earth grounds.
Flashes full-scale. |
Pt 100 RTD Input
| RTD Alpha |
Range |
Error at 25°C
.01% FS
|
DIN
.00385 |
-202°C to
+850°C
-331°F to +1562°F |
±0.03°C
±0.05°F |
ANSI
.003925 |
-202°C to
+631°C
-331°F to +1168°F |
±0.04°C
±0.07°F |
Applicable
to all RTD types |
Calibration, DIN
Calibration ANSI
Configuration
Excitation current
Overall accuracy
Span tempco
Zero tempco
Overvoltage protection
Open sensor indication |
IEC 751 (IPTS-68)
NIST Monograph 126
2, 3 or 4-wire connection
0.2 mA
±0.01% of full span ±2 counts
±0.003% of reading/ºC
±0.03 deg/deg
125 Vac
Flashes full-scale |
|
Sensor lead resistance tempco per conductor |
2-wire, 10 mdeg/W/deg up to 10 W
3 & 4-wire, 10 mdeg/W/deg up to 100 W |
Thermocouple & RTD
| Display |
Readout
Color
Indicators |
5
digits, 7-segment, 14.2 mm (.56")
Red or green LED
Minus sign, 2 red LED lamps |
|
A-to-D Conversion |
Technique
A-to-D Rate
Output Update
Display Update |
Concurrent Slope (Pat 5,262,780)
60/s at 60 Hz, 50/s at 50 Hz
56/s at 60 Hz, 47/s at 50 Hz
3.5/s at 60 Hz, 3/s at 50 Hz |
|
Power |
Voltage, standard
Voltage, optional
Frequency
Power Isolation |
95-240 Vac ±10% or 90-300 Vdc (DC operation
not UL approved)
12-30 Vac or 10-48 Vdc
DC or 47-63 Hz
250V rms working, 2.3 kV rms per 1 min test |
|
Analog Output (optional) |
Output
levels
Compliance
Scaling
Resolution
Isolation |
0-10V,
0-20 mA, 4-20 mA (jumper selectable)
2 mA at 10V ( > 5 kOhm), 12V at 20 mA ( < 60 ohms)
Zero and full scale adjustable from -99999 to +99999
12 bits (0.025% of full scale)
250V rms working, 2.3 kV rms per 1 min test |
|
Dual Contact Relay Outputs (optional) |
Relay
Type
Load Rating
Isolation |
Form C
8A at 250 Vac or 24 Vdc
250V rms working, 2.3 kV rms per 1 min test |
|
Dual Solid State Relay Outputs (optional) |
Relay Type
Load Rating
Isolation |
SPST, normally open,
Form A
120 mA at 130 Vac or 170 Vdc, 28 ohms in series
250V rms working, 2.3 kV rms per 1 min test |
|
Serial Data I/O (optional) |
Board Selections
Protocols
Data Rates
Digital Addresses
Isolation |
RS232, RS485, Modbus RS485
Modbus RTU, Modbus ASCII, simpler Laurel ASCII
300 to 19200 bps
247 (Modbus), 31 (Laurel ASCII),
250V rms working, 2.3 kV rms per 1 min test |
|
Environmental |
Operating Temp.
Storage Temp.
Relative Humidity
Protection |
0°C to
60°C
-40°C to 85°C
95% at 40°C, non-condensing
NEMA-4X (IP-65) when panel mounted |
|

RTD Connections with
Excitation & Lead Compensation
|
The Laureate temperature meter
allows 2-, 3- and 4-wire RTD hookup to the J5 connector. The meter applies an excitation
current of 0.2 mA, which it monitors to make ratiometric corrections for excitation supply
variations.
In 2-wire hookup, the meter
senses the voltage drop across the 100 ohm RTD and both lead wires. The effect of the lead
wires can be measured and subtracted by shorting out the RTD during meter setup.
In 3- and 4-wire hookup, the
meter senses the voltage drop across the 100 ohm RTD and both lead wires as well as the
voltage drop across the RTD and one lead wire. This allows the meter to determine the effect of
one lead wire and mathematically subtract the effect of both lead wires. |
|
|

Application Examples

Operation as a 4-20 mA Transmitter
With the optional analog
output board, Laureate temperature meters can serve as superb, isolated 4-20 mA
transmitters. The analog output is scaled to the display, which is linearized to ºC or
ºF and is exceptionally accurate. The analog output further tracks the high read rate of
the meter, at up to 60 readings
per second at 60 Hz power. Fast update rates are beneficial in many closed-loop and PID
control applications.
Operation as a
Fast Controller
With the dual contact
relay or dual solid state relay output board options, Laureate temperature meters can
serve as extremely fast and accurate ON/OFF controllers
for closed-loop temperature control.
Multiple setpoint operating modes are
individually selectable for each relay, as explained in the dual-setpoint controller
section. Relay duty cycles and chatter can be minimized with programmable hysteresis and
time delays. High duty cycles and extremely fast response times are possible with the
solid state relay, which has a typical response time of only 17 ms.
Operation as a Supervisory
Monitor
By using the optional
dual contact relay or dual solid state relay output options, Laureate temperature meters
can monitor processes and provide alarms or shutoffs when these processes exceed normal
limits.
A band deviation operating mode can be
selected for each relay, where an alarm is generated whenever the reading is a selected
number of counts above or below the setpoint. Relay operation can be selected as latching
or non-latching. When an alarm or shutdown condition is reached, a latched output will
remain in the alarm condition until it is reset by a front panel pushbutton, via the
serial interface, or via the rear connector.
|

Ordering
Guide
Laureate™ Thermocouple & RTD Temperature Panel Meters
Click
on the radio buttons to build a model number with pricing.
|