| Approvals |
| Types |
Produced to IPC 610 Class 2 Standard
UL ISO9001:2008 QA |
| Pulse Inputs |
Number of Inputs
Signal Types
Frequency Range
Debounce |
4
Configurable for contact closures, NPN or PNP proximity switches,
5V logic pulses, 24V pulses, quadrature
0-40 kHz in totalizing mode
Programmable to eliminate false counting from contact bounce. |
| Display |
Number of Digits
Digit Height
Digit Color
Brightness
Numeric Format
Display Update Rate
|
4 or 6
57 mm (2-1/4"), 102 mm (4.0"), 150 mm (5.9"), or 200 mm (7.9")
Red
Variable
8.8.8.8. or 8.8.8.8.8.8.
3 readings/second above 3 Hz, otherwise signal pulse rate. |
| User Controls |
Scaling
Filtering
Rounding
Linearization |
Digital direct or theoretical scaling with scale & offset.
Digital filtering, time constants adjustable from 0 to 25 sec.
Selectable last-digit rounding of 1, 2, 5, 10, 20, 50 units.
Up to 10 points, direct or theoretical calibration. |
| Logic Inputs |
Front Panel Controls
Logic Functions
Logic Levels |
Four buttons to set time, date, alarms, etc.
Three logic inputs, individually configurable for Hold, Reset, Tare, Peak / Valley, Net/Gross, Memory Address.
Normally open, NPN or contact closure input to activate.
5V open circuit, 1 mA switched current. |
| Power |
AC Power (standard)
DC Power (option)
Max Consumption |
100-240 Vac
11-30 Vdc
30 VA |
| Analog Output Option |
Output Levels
Resolution
Accuracy
Stability
Output Isolation
Scaling
Special Features |
0-20 / 4-20 mA into 0 to 500Ω, 0.4 µA resolution.
0-10V into loads > 600Ω, 0.2 mV resolution.
-10 to+10V into loads > 600Ω, 0.4 mV resolution.
16 bits
0.1% of range
50 ppm/°C
Isolated from input and power
Digitally scalable
Forward or reverse action possible.
Can be set to operate from net or gross value. |
| Alarm Output Option |
Relay Type
Special Features |
2 Alarms rated 5A, 250VAC, SPDT
Adjustable hysteresis
In-flight compensation facility.
Energize or de-energize on trip.
Adjustable timers to set energize and de-energize delays. Can also be set to pulse for applications needing less than 100% duty cycle.
In-band and out-of-band alarm function.
Manual and automatic in-flight compensation.
Can be set to operate from net or gross value. |
| Serial Data Output Option |
Output Types
Special Features |
RS232 or RS485, addressable, on demand or continuous output.
Can include time and date with RTC option fitted.
Can be set to operate from net or gross value. |
| Environmental |
Storage Temp.
Operating Temp.
Sealing
Mounting |
-20°C to +70°C
0C to 50°C, non-condensing
IP65 standard, all-round
Wall mount, suspension mount, panel mount |