MAGNA Series, Serial Input Large Digit Displays

Numeric Displays for Computers, PLCs, Transmitters & Smart Sensors & Transmitters with a Serial Output
Approvals
Types Produced to IPC 610 Class 2 Standard
UL ISO9001:2008 QA
Serial Data Input
Serial Data Types
Serial Connector
Displayed Information
RS232 or RS485 (specify at time of order)
Detachable plug-in screw terminals
ASCII: Displays any character within 7-segment display limitations.
Quant: Displays only numeric ASCII values.
Qa.Tot: Quantity totalizer. Can be used to accumulate weight values, for example after each batch. Uses a contact closure to trigger addition.
Settable Parameters
Baud Rate
Data Format
Termination Character
Reject Characters
Addressing
300 to 115200
701, 7e1, 7n2, 801, 8e1, 8n1, 8n2
Hex 00 to FF
Counted from termination character
00 (wildcard) to F7
Display
Number of Digits
Digit Height
Digit Color
Brightness
Clock Format
Display Update Rate
4 or 6
57 mm (2-1/4"), 102 mm (4.0"), 150 mm (5.9"), or 200 mm (7.9")
Red
Variable
HH:MM or HH:MM:SS
10 readings/second
Logic Inputs
Front Panel Controls
Logic Functions
  
Logic Levels
Four buttons to set time, date, alarms, etc.
Three logic inputs, individually configurable for Hold, Reset, Tare, Peak / Valley, Net/Gross, Memory Address.
Normally open, NPN or contact closure input to activate.
5V open circuit, 1 mA switched current.
Power
AC Power (standard)
DC Power (option)
Max Consumption
100-240 Vac
11-30 Vdc
30 VA
Analog Output Option
Output Levels
  
  
Resolution
Accuracy
Stability
Output Isolation
Scaling
Special Features
0-20 / 4-20 mA into 0 to 500Ω, 0.4 µA resolution.
0-10V into loads > 600Ω, 0.2 mV resolution.
-10 to+10V into loads > 600Ωs, 0.4 mV resolution.
16 bits
0.1% of range
50 ppm/°C
Isolated from input and power
Digitally scalable
Forward or reverse action possible.
Can be set to operate from net or gross value.
Alarm Output Option
Relay Type
Special Features
2 Alarms rated 5A, 250VAC, SPDT
Adjustable hysteresis
In-flight compensation facility.
Energize or de-energize on trip.
Adjustable timers to set energize and de-energize delays. Can also be set to pulse for applications needing less than 100% duty cycle.
In-band and out-of-band alarm function.
Manual and automatic in-flight compensation.
Can be set to operate from net or gross value.
Serial Data Output Option
Output Types
Special Features
RS232 or RS485, addressable, on demand or continuous output.
Can include time and date with RTC option fitted.
Can be set to operate from net or gross value.
Environmental
Storage Temp.
Operating Temp.
Sealing
Mounting
-20°C to +70°C
0C to 50°C, non-condensing
IP65 standard, all-round
Wall mount, suspension mount, panel mount