Laureate™ DC Voltage & Current
Digital Panel Meters
High accuracy, high read rate, control outputs

Standard Features
- 0.2, 2, 20, 200,
300V & 600V DC voltage ranges
- 2, 20, 200 mA and 5A
DC current ranges
- All ranges factory calibrated
- 99.99% full scale accuracy
- 4-1/2 digit resolution to
±19,999 for readout in mV, V, mA or A
- 1 Gohm input impedance on 200 mV and 2 V scales
- Front panel scalable
to ±99,999 for external current shunts
- Up to 60 conversions per second
- Peak or valley
capture & display
- Selectable adaptive digital
filter
- Selectable fixed zero or active
least significant digit
- Universal AC power, 85-264 Vac
- 5, 10 or 24 Vdc excitation
supply
- External controls for reset,
meter hold and decimal points
-
NEMA 4X, 1/8 DIN case
- Certified to UL 61010C-1 (UL mark), EN
61010-1 (CE mark), and RoHS)
Options:
- Low voltage
power: 10-48 Vdc or 12-32 Vac
-
2 or 4 output relays, electromechanical or
solid state
- Analog output: Isolated, 4-20 mA, 0-20 mA, 0-10V,
-10 to +10V
- Serial communications: RS232, RS485, Modbus RS485,
USB, USB-to-RS485 converter
|

Description

Laureate DC voltage and current panel meters with a DC signal
conditioner board combine high accuracy with high read rate and a wide range of isolated
output options for computer interface and control. Accuracy is 99.99% of full scale
±2 counts.
- DC voltmeter operation (selected by
jumpers)
provides and six full-scale voltage ranges from
200.00 mV with 10 mV resolution to 600.0 V with 100 mV resolution. The 200.00 mV and 2.000
V ranges provide a high input impedance of 1 Gohm to minimize the load on the
voltage signal.
- DC ammeter operation (selected by
jumpers) provides four full-scale current ranges from 2.0000
mA with 0.1 mA resolution to 5.000 A with 1 mA resolution. The 5.000 A range measures the IR drop across a built-in 10 milliohm current shunt.
All voltage and current
ranges are factory calibrated, with calibration factors for each range
stored in an EEPROM on the signal conditioner board. This allows ranges and
signal conditioner boards to be changed in the field without recalibrating the meter.
External
current shunts are fully supported. Scaling from full-scale millivolts,
such as 50 mV or 100 mV,
to amperes is easily accomplished from the front panel of the meter. The
scalable readout is five full digits up to ±99,999 counts.
High read rates
at up to 60 or 50 conversions per second while integrating the signal
over a full power cycle are provided by Concurrent Slope (US Pat
5,262,780) analog-to-digital conversion. High
read rates are ideal for peak or valley capture, real-time computer interface, and control.
Peak and valley values are
automatically captured. These may be displayed via a front panel pushbutton command or a
control signal at the rear connector, or be transmitted as serial data.
Digital filtering is selectable for
electrically noisy environments,
including a batch averaging filter and an adaptive moving average filter
which provides a choice of 8 time constants from 80 ms to 9.6 s. When a significant
change in signal level occurs, that filter adapts by briefly switching to the shortest time
to follow the change, then reverts back to the selected time constant.
In a selectable Auto filter mode, the filter time constant is automatically
selected based on detected signal noise.
An isolated 5, 10 or 24 Vdc
isolated excitation output is standard to power external transducers
and transmitters. In many cases, this output can eliminate the need for an external
power supply.
Designed for flexibility. Optional
plug-in boards for communications and control include an
analog output board, dual or
quad relay boards,
and serial communications boards. Laureates may be powered from
85-264 Vac or optionally
from 12-32 Vac or 10-48 Vdc. The display is available
with red or green LEDs. The 1/8 DIN case meets NEMA 4X (IP65) specifications from the front
when panel mounted. Any setup functions and front panel keys can be
locked out for simplified usage and security.
|

Specifications
DC Voltage
| DC
Voltage Range |
Resolution |
Input
Resistance |
Error
at 25°C
± 2 cts |
200.00
mV
2.000 V
20.000 V
200.00 V
600.0 V *
300.0 V |
10
µV
100 µV
1 mV
10 mV
100 mV
100 mV |
1
GΩ
1 GΩ
10 MΩ
10 MΩ
10 MΩ
10 MΩ |
0.01% FS
0.01% FS
0.01% FS
0.01% FS
0.02% FS
0.02% FS |
| |
|
* Range does not include U/L certification. |
DC Current
| DC
Current Range |
Resolution |
Input
Resistance |
Error
at 25°C
± 2 cts |
2.0000
mA
20.000 mA
200.00 mA
5.000 A |
0.1
µA
1.0 µA
10 µA
1.0 mA |
100
Ω
10 Ω
1 Ω
0.01 Ω |
0.01% FS
0.01% FS
0.01% FS
0.04% FS |
DC Voltage & Current
|
Display |
|
Readout
Range
Indicators |
5 LED digits, 7-segment, 14.2 mm (.56"), red
or green.
-99999 to 99999 or -99990 to 99990
(count by 10)
Minus sign, 2 red LED lamps |
|
A-to-D Conversion |
|
Technique
A-to-D Rate
Output Update
Display Update |
Concurrent Slope (Pat 5,262,780)
60/s at 60 Hz, 50/s at 50 Hz
56/s at 60 Hz, 47/s at 50 Hz
3.5/s at 60 Hz, 3/s at 50 Hz |
|
Accuracy |
|
Error at 25°C
Span Tempco
Zero Tempco |
0.01% FS
± 2 counts (except 5A range)
0.003% of reading/°C
0.1 count/°C |
|
Noise Rejection |
|
CMR, DC to 60 Hz
NMR at 50/60 Hz |
130 dB
90 dB with min filtering |
|
Maximum Signal |
|
Max applied voltage
Current
protection |
600 Vac for 20, 200 and 300 V ranges, 125 Vac for other
ranges
25x for 2 mA, 8x for 20 mA, 2.5x for 200 mA, 1x for 5 A |
|
Power |
|
Voltage, standard
Voltage, optional
Frequency
Power Isolation |
85-264 Vac or 90-300 Vdc (DC operation
not UL approved)
12-32 Vac or 10-48 Vdc
DC or 47-63 Hz
250V rms working, 2.3 kV rms per 1 min test |
|
Excitation Output (standard) |
|
5 Vdc
10 Vdc
24 Vdc
Output Isolation |
5 Vdc ±5%, 100 mA
10 Vdc ±5%, 120 mA
24 Vdc ±5%, 50 mA
50 Vdc to meter ground |
|
Analog Output (optional) |
|
Output Levels
Current compliance
Voltage compliance
Scaling
Resolution
Isolation |
4-20 mA, 0-20 mA, 0-10V,
-10 to +10V (jumper selectable)
2 mA at 10V ( > 5 kOhm load)
12V at 20 mA (< 60 ohm load)
Zero and full scale adjustable from -99999 to +99999
16 bits (0.0015% of full scale)
250V rms working, 2.3 kV rms per 1 min test |
|
Relay Outputs (optional) |
|
Relay
Types
Current Ratings
Output common
Isolation |
2 Form C
contact
relays or 4 Form A contact relays (NO)
2 or 4 Form A, AC/DC solid state relays (NO)
8A at 250 Vac or 24 Vdc for contact relays
130 mA at 140 Vac or 180 Vdc for solid state relays
Isolated commons for dual relays or each pair of quad relays
250V rms working, 2.3 kV rms per 1 min test |
|
Serial Data I/O (optional) |
|
Board Selections
Protocols
Data Rates
Digital Addresses
Isolation |
RS232, RS485, Modbus RS485, USB, USB-to-RS485
converter
Modbus RTU, Modbus ASCII, simpler Laurel ASCII
300 to 19200 bps
247 (Modbus), 31 (Laurel ASCII),
250V rms working, 2.3 kV rms per 1 min test |
|
Signal Connections |
|
 |
|
Environmental |
|
Operating Temp.
Storage Temp.
Relative Humidity
Protection |
0°C to
60°C
-40°C to 85°C
95% at 40°C, non-condensing
NEMA-4X (IP-65) when panel mounted |
|

Ordering
Guide
Laureate™ DC Voltage & Current Panel Meters
Click on the radio buttons to build a model number with pricing (shown below the Ordering Guide).
|