Pulse Input or Analog Input Batch Controller
Automatic batch control for repetitive liquid fill operations

Input Batch Controller
CE Mark   UL Mark RoHS Mark Made in California Logo

Standard Features

Product Links

Specs
Mechanical
Serial I/O options
Power options
Relay options
Analog output option
Meter manual
Serial manual
Modbus manual
Setup software
Pricing

  • Provides automatic control for repetitive liquid fill operations
  • Accepts turbine flow meter pulse signals from 0 Hz to 1 MHz
  • Accepts 4-20 mA, 0-1 mA or 0-10V analog flow meter signals
  • 6-digit display scalable to ±999,999
  • Selectable display of batch total, grand total, number of batches, or flow rate
  • Counts up from 0 to preset or down from preset to 0
  • Dual 8A relays for control with settable delay between cycles
  • Isolated 5, 10 or 24 Vdc excitation supply
  • Universal AC power, 85-264 Vac
  • External controls for reset, meter hold and decimal points
  • NEMA 4X, 1/8 DIN case
  • Certified to UL 61010C-1 (UL mark), EN 61010-1 (CE mark), and RoHS
    Options:
  • Low voltage power: 10-48 Vdc or 12-32 Vac
  • 2 or 4 output relays, electromechanical or solid state
  • 1 or 2 analog outputs: Isolated, 4-20 mA, 0-20 mA, 0-10V, -10 to +10V
  • Serial communications: RS232, RS485, Modbus RS485, USB, USB-to-RS485 converter

Description

Batch controller by Laurel Electronics

The Laureate batch controller is a low cost, powerful and highly accurate batching controller for repetitive fill operations. It can use the Laureate FR dual channel pulse input signal conditioner for use with turbine flow meters, or the Laureate V-to-F analog signal conditioner for use with 4-20 mA, 0-1 mA or 0-10V conditioned flow meter signals. Relay control can be provided by two or four 8A contact relays, or by two or four 130 mA AC/DC solid state relays. Fill operations are repeated continually with a programmable delay from 10 ms to 199.99 sec, or based on an external control input.

Three items are tracked by the batch control software. These can each be scaled to engineering units of total or flow rate and displayed by the controller's six-digit LED display:

  • Item #1 is the current batch total, which can be set up to count up from zero to a preset limit, or down from a preset limit to zero.
  • Item #2 can be assigned to grand total or number of batches.
  • Item #3 is the flow rate.
Two or four relays can be used. Relay #1 is assigned to batch total to control the filling operation. Relays #2, #3 and #4 can each be assigned by the user to Items #1, #2 or #3. For example, Relay #2 can be assigned to Item #1 (batch total) with a lower setpoint to serve as a pre-warn and slow down the fill rate near the batch setpoint, and  Relay #3 can be assigned to the total number of batches to terminate the batching when a present number of bottles have been filled.

An optional serial communications board allows the batch controller to transmit Items #1, #2 and #3, as well as peak for item #3 (rate). If required, all four items can be displayed simultaneously by augmenting the batch controller with up to three Laureate remote displays. Each of these can have its own analog output and relays for alarm or control.

pulse input batch controllerBatch Control with Turbine Flowmeters

The pulse-input batch controller utilizes the FR dual channel signal conditioner, which accepts pulses from turbine flow meters and most industrial transducers with a pulse output such as proximity switches with PNP or NPN output, TTL or CMOS logic, or magnetic pickup pulses down to 12 mV. The same signal is applied in parallel to the A and B input channels, which are used independently. Either channel can accept pulse rates from 0.005 Hz to 250 kHz, which exceeds the working range of turbine flow meters.

  • Channel A is used for totalizing. The measured total is scaled mathematically for control and display of volume in engineering units, such as liters.

  • Channel B is used for rate. The pulse frequency is determined by timing an integral number of periods over a specified gate time (plus 30 ms and 0-2 periods), and then taking the inverse of period. The inverse period approach allows much greater accuracy and faster update times than conventional rate meters which count signal pulses over a specified time interval. Update times can be as high as 25/sec. Rate in engineering units, such as liters per second, is obtained by multiplying the input by a scale factor.

DC Ammeter fully ScalableBatch Control with Conditioned Flow Signals

The analog input batch controller utilizes the Laureate VF voltage-to-frequency converter signal conditioner to accept 4-20 mA, 0-1 mA or 0-1V conditioned flow meter signals, which it then converts to a frequency of 10 kHz to 110 kHz. This allows the controller to totalize flow, to count up to a preset value, or to count down to zero from a preset value for batch control. Again, one of the relays is dedicated to ON/OFF batch control, while the other relay is available to slow down rate near the setpoint or to provide another alarm or control function based on rate or total.

Other Features

The 1/8 DIN case of Laureate meters and counters meets NEMA 4X (IP-65) standards from the front for high pressure wash-down when panel mounted. All power and signal connections are via UL / VDE / CSA rated screw clamp plugs, which are standard.

Batch Controller Specifications

Display

Readout
Display Range
Zero Adjust
Span Adjust
Indicators

6 LED digits, 7-segment, 14.2 mm (.56"), red or green
-999999 to +999999, XXXXEX scientific notation beyond 999999
-999999 to +999999
0 to 999999
Four LED lamps

Pulse Inputs (FR signal conditioner)

Signal Types

Ch A Frequency, Max
Ch B Frequency, Max
Signal Ground
Minimum Signal
Maximum Signal
Maximum Frequency

Conversion Technique
Delay between batches

AC, pulses from NPN, PNP transistors, contact closures,
magnetic pickups.
1 MHz
250 kHz
Common ground for channels A & B
Nine ranges from (-12 to +12 mV) to (+1.25 to +2.1V)
250 Vac
1 MHz, 30 kHz,  250 Hz (selectable)
Inverse period
Selectable 10 ms to 199.99 s

Analog Input (V-to-F signal conditioner)

Signal Types
Conversion Technique
Update Rate
Gate Time

0-1 mA, 4-20 mA, 0-10V
Inverse period applied to 10 kHz- 110 kHz
5
0 ms (max)
Selectable 10 ms to 199.99 s

Power

Voltage, standard
Voltage, optional
Frequency
Power Isolation

85-264 Vac or 90-300 Vdc (DC operation not UL approved)
12-32 Vac or 10-48 Vdc
DC or 47-63 Hz
250V rms working, 2.3 kV rms per 1 min test

Excitation Output (standard)

5 Vdc
10 Vdc
24 Vdc
Output Isolation

5 Vdc ±5%, 100 mA
10 Vdc ±5%, 120 mA
24 Vdc ±5%, 50 mA
50 Vdc to meter ground

Analog Output (optional)

Output Levels
 
Current compliance
Voltage compliance
Scaling
Resolution
Isolation

4-20 mA, 0-20 mA, 0-10V, -10 to +10V (single-output option)
4-20 mA, 0-20 mA, 0-10V (dual-output option)
2 mA at 10V ( > 5 kOhm load)
12V at 20 mA ( < 600 Ohm load)
Zero and full scale adjustable from -99999 to +99999
16 bits (0.0015% of full scale)
250V rms working, 2.3 kV rms per 1 min test
(dual analog outputs share the same ground)

Relay Outputs (minimum of 2 relays required)

Relay Types
 
Current Ratings
 
Output common
Isolation

2 Form C contact relays or 4 Form A contact relays (NO)
2 or 4 Form A, AC/DC solid state relays (NO)
8A at 250 Vac or 24 Vdc for contact relays
130 mA at 140 Vac or 180 Vdc for solid state relays
Isolated commons for dual relays or each pair of quad relays
250V rms working, 2.3 kV rms per 1 min test

Serial Data I/O (optional)

Board Selections
Protocols
Data Rates
Digital Addresses
Isolation

RS232, RS485, Modbus RS485, USB, USB-to-RS485 converter
Modbus RTU, Modbus ASCII, simpler Laurel ASCII
300 to 19200 bps
247 (Modbus), 31 (Laurel ASCII),
250V rms working, 2.3 kV rms per 1 min test

Environmental

Operating Temperature
Storage Temperature
Relative Humidity
Protection

0°C to 60°C
-40°C to 85°C
95% at 40°C, non-condensing
NEMA-4X (IP-65) when panel mounted

Signal Connections

Signal connections to Laurel pulse input batch controller

Typical Batching Applications

Drum Filling Application Utilizing Two Relay Outputs

Drum filling batch controller application utilizing two relay outputs In this drum filling application, the Laureate pulse-input batch controller utilizes uses its two relays to control a pump. The Prewarn relay slows down the pump near the preset to avoid overshoot. The Batch relay stops the pump at the preset.

Controlling Chemical Mixing of Materials

Controlling mixing of materials using two Laureate batch controllers Multiple Laureate batch controllers can be used in combination to control the mixing of materials in the proper ratio. Each feed line is equipped with its own pump, flowmeter, and Laureate.

Controller setup and monitoring of the mixing operation are facilitated by optional serial communications. RS-485 allows a single data line to handle multiple controllers.

Up-Counting Batch Control

Up-counting batch controller using the Laureate Batch Controller In up-counting batch control, the Laureate counts up from zero to a preset maximum. A prewarn level is available to slow down filling near the preset to avoid overshoot. A time delay can be programmed from the end of each batch to the start of the next batch.

Down-Counting Batch Control

Down-counting batch control using the Laureate Batch Controller In down-counting batch control, the Laureate counts down from the preset maximum to zero. A prewarn level is available to slow down filling or emptying near zero. Again, a time delay can be programmed from the end of each batch to the start of the next batch.

Discrete Filling and Batch Counting

Discrete filling and batch counting using the Laureate Batch Controller The Laureate batch controller is ideal for discrete manufacturing as well as repetitive fill operations. In this example, the Laureate counts bottles which it then groups into sixpacks. Its Grand Total capability can be used to track bottles or sixpacks.

Ordering Guide
Laureate Pulse Input & Analog Input Batch Controller

 Click on the radio buttons to build a model number with pricing (shown below the Ordering Guide).

Quantity
Main
Board
L7  Extended Main Board, Green LEDs
L8  Extended Main Board, Red LEDs
$270
$270
Power Isolated 85-264 Vac
Isolated 12-32 Vac or 10-48 Vdc
NC
$30
Relay
Output
  None
Two 8A Contact Relays
Two Solid State Relays
Four 8A Contact Relays
Four Solid State Relays
NC
$80
$55

$100
$75
Analog
Output
None
Single isolated 4-20 mA, 0-20 mA, 0-10V, -10 to +10V
Dual isolated 4-20 mA, 0-20 mA, 0-10V
NC
$90

$135
Digital
Interface
None
Isolated RS-232
Isolated RS-485
Isolated Modbus RS-485
USB
USB-to-RS485 converter
NC
$60

$80

$90

$60

$100
Input
Type
Pulse Rate or Totalizing
FR  Dual-Channel Frequency
 
NC
Voltage-to-Frequency Converter
VF1  V-to-F Converter, 4-20 mA
VF2  V-to-F Converter, 0-1 mA
VF3  V-to-F Converter, 0-10 V
VF4  V-to-F Converter, Special Range
In the write-in field of your order, specify min input, min reading; max input, max reading. Component changes by the factory may be required.
 
NC

NC

NC

$35
Add-on
Options
BL  Blank lens without button pads
CBL01  RJ11-to-DB9 cable
CBL02  USB-to-DB9 adapter
CBL05 
USB Cable, A to B
IPC 
Clear front panel cover sealed to NEMA 4X / IP65
BOX1 
NEMA-4X wall-mount enclosure with 1/8 DIN cutout
BOX2 
BOX1 plus IPC
NC
$19

$39

$15

$40

$140

$180
 

Configured model number

L70100FR

Configured price per model

$270

Quantity

1

Extended price

$270

 

 

  