Pulse Input or Analog Input Batch Controller
Automatic batch control for repetitive liquid
fill operations

Standard Features
- Provides automatic control for
repetitive liquid fill operations
- Accepts
turbine flow meter pulse signals from 0 Hz to 1 MHz
- Accepts 4-20 mA, 0-1 mA or 0-10V
analog flow meter signals
- 6-digit display scalable to
±999,999
- Selectable display of batch
total, grand total, number of batches, or flow rate
- Counts up from 0 to
preset or
down from preset to 0
- Dual 8A relays
for control with settable delay between cycles
- Isolated 5, 10 or 24 Vdc
excitation supply
-
Universal AC power, 85-264 Vac
- External controls for reset,
meter hold and decimal points
-
NEMA 4X, 1/8 DIN case
- Certified to UL 61010C-1 (UL mark), EN 61010-1 (CE mark),
and RoHS
Options:
- Low voltage power: 10-48 Vdc or 12-32
Vac
-
2 or 4 output relays, electromechanical or
solid state
- 1 or 2 analog outputs: Isolated, 4-20 mA, 0-20 mA, 0-10V, -10
to +10V
- Serial communications: RS232, RS485, Modbus RS485,
USB, USB-to-RS485 converter
|

Description

The Laureate batch controller is a low cost, powerful and highly
accurate batching controller for repetitive fill operations. It can use
the Laureate FR dual channel
pulse input signal conditioner for use with turbine flow meters, or the
Laureate V-to-F analog signal conditioner for
use with 4-20 mA, 0-1 mA or 0-10V conditioned flow meter signals.
Relay control can be provided by two or four 8A
contact relays, or
by two or four
130 mA AC/DC solid state relays.
Fill operations are repeated continually with a programmable delay from 10
ms to 199.99 sec, or based on an external control input.
Three items are tracked by the batch
control software. These can each be scaled to engineering units of
total or flow rate and displayed by the controller's six-digit LED
display:
-
Item #1 is the
current batch total, which can be set up to count up from zero to a
preset limit, or down from a preset limit to zero.
-
Item #2 can be
assigned to grand total or number of batches.
-
Item #3 is the
flow rate.
Two or four relays can be used. Relay
#1 is assigned to batch total to control the filling operation. Relays
#2, #3 and #4 can each be assigned by the user to Items #1, #2 or #3.
For example, Relay #2 can be assigned to Item #1 (batch total) with a
lower setpoint to serve as a pre-warn and slow down the fill rate near
the batch setpoint, and Relay #3 can be assigned to the total
number of batches to terminate the batching when a present number of
bottles have been filled.
An optional serial communications board
allows the batch controller to transmit
Items #1, #2 and #3, as well as peak for item #3 (rate). If required, all four items can be
displayed simultaneously by augmenting the batch controller with up to three
Laureate remote displays. Each of these can have its own analog output and relays for alarm or
control.
Batch
Control
with Turbine Flowmeters
The pulse-input batch controller utilizes the FR dual channel signal conditioner,
which accepts pulses from turbine flow meters and most industrial
transducers with a pulse output such as proximity switches with PNP or NPN output, TTL or
CMOS logic, or magnetic pickup pulses down to 12 mV. The same signal is applied in
parallel to the A and B input channels, which
are used independently. Either channel can accept pulse
rates from 0.005 Hz to 250 kHz, which exceeds the working range of turbine
flow meters.
-
Channel A is used for
totalizing. The measured total is scaled mathematically for control and display
of volume in
engineering units, such as liters.
-
Channel B
is used for rate.
The pulse frequency is determined by timing an integral number of periods over a specified
gate time (plus 30 ms and 0-2 periods), and then taking the inverse of period. The inverse
period approach allows much greater accuracy and faster update times than conventional
rate meters which count signal pulses over a specified time interval. Update times can be
as high as 25/sec. Rate in engineering units, such as liters per second, is obtained by
multiplying the input by a scale factor.
Batch Control with Conditioned Flow Signals
The analog input batch controller utilizes the Laureate VF
voltage-to-frequency converter signal conditioner to accept 4-20 mA, 0-1
mA or 0-1V conditioned flow meter signals, which it then converts to a
frequency of 10 kHz to 110 kHz. This allows the controller to totalize
flow, to count up to a preset value, or to count
down to zero from a preset value for batch control. Again, one of the
relays is dedicated to ON/OFF batch control, while the other relay is available to slow down
rate near the setpoint or to provide another alarm or control function based on rate or
total.
Other Features
The
1/8 DIN case
of Laureate meters and counters
meets NEMA 4X (IP-65) standards from the front for high pressure wash-down when panel
mounted. All power and signal connections are via UL / VDE / CSA rated screw clamp plugs,
which are standard.
|

Batch Controller Specifications
|
Display |
|
Readout
Display Range
Zero Adjust
Span Adjust
Indicators |
6 LED digits, 7-segment, 14.2 mm (.56"), red or
green
-999999 to +999999, XXXXEX scientific notation beyond 999999
-999999 to +999999
0 to 999999
Four LED lamps |
|
Pulse Inputs (FR signal conditioner) |
|
Signal Types
Ch A Frequency, Max
Ch B Frequency, Max
Signal Ground
Minimum Signal
Maximum Signal
Maximum Frequency
Conversion Technique
Delay between batches |
AC, pulses from NPN, PNP transistors,
contact closures,
magnetic pickups.
1 MHz
250 kHz
Common ground for channels A & B
Nine ranges from (-12 to +12 mV) to (+1.25 to +2.1V)
250 Vac
1 MHz, 30 kHz, 250 Hz (selectable)
Inverse period
Selectable 10 ms to 199.99 s |
|
Analog Input (V-to-F signal conditioner) |
|
Signal Types
Conversion
Technique
Update Rate
Gate Time |
0-1 mA, 4-20 mA, 0-10V
Inverse period applied to 10 kHz- 110 kHz
50 ms (max)
Selectable 10 ms to 199.99 s |
|
Power |
|
Voltage, standard
Voltage, optional
Frequency
Power Isolation |
85-264 Vac or 90-300 Vdc (DC operation
not UL approved)
12-32 Vac or 10-48 Vdc
DC or 47-63 Hz
250V rms working, 2.3 kV rms per 1 min test |
|
Excitation Output (standard) |
|
5 Vdc
10 Vdc
24 Vdc
Output Isolation |
5 Vdc ±5%, 100 mA
10 Vdc ±5%, 120 mA
24 Vdc ±5%, 50 mA
50 Vdc to meter ground |
|
Analog Output (optional) |
|
Output Levels
Current compliance
Voltage compliance
Scaling
Resolution
Isolation |
4-20 mA, 0-20 mA, 0-10V, -10
to +10V (single-output option)
4-20 mA, 0-20 mA, 0-10V (dual-output option)
2 mA at 10V ( > 5 kOhm load)
12V at 20 mA ( < 600 Ohm load)
Zero and full scale adjustable from -99999 to +99999
16 bits (0.0015% of full scale)
250V rms working, 2.3 kV rms per 1 min test
(dual analog outputs share the same ground) |
|
Relay Outputs (minimum
of 2 relays required) |
|
Relay
Types
Current Ratings
Output common
Isolation |
2 Form C
contact
relays or 4 Form A contact relays (NO)
2 or 4 Form A, AC/DC solid state relays (NO)
8A at 250 Vac or 24 Vdc for contact relays
130 mA at 140 Vac or 180 Vdc for solid state relays
Isolated commons for dual relays or each pair of quad relays
250V rms working, 2.3 kV rms per 1 min test |
|
Serial Data I/O (optional) |
|
Board Selections
Protocols
Data Rates
Digital Addresses
Isolation |
RS232, RS485, Modbus RS485, USB, USB-to-RS485
converter
Modbus RTU, Modbus ASCII, simpler Laurel ASCII
300 to 19200 bps
247 (Modbus), 31 (Laurel ASCII),
250V rms working, 2.3 kV rms per 1 min test |
|
Environmental |
|
Operating Temperature
Storage Temperature
Relative Humidity
Protection |
0°C to 60°C
-40°C to 85°C
95% at 40°C, non-condensing
NEMA-4X (IP-65) when panel mounted |
|
Signal Connections |
|
 |

|
Typical
Batching Applications |
Drum Filling Application Utilizing Two Relay Outputs |
 |
In this drum filling application, the Laureate
pulse-input batch controller utilizes uses its two relays to control a pump. The
Prewarn relay slows down the pump near the preset to avoid overshoot. The Batch relay
stops the pump at the preset. |
Controlling Chemical Mixing of Materials |
 |
Multiple Laureate batch controllers can be used in
combination to control the mixing of materials in the proper ratio. Each feed line is
equipped with its own pump, flowmeter, and Laureate. Controller
setup and monitoring of the mixing operation are facilitated by optional serial
communications. RS-485 allows a single data line to handle multiple controllers. |
Up-Counting Batch Control |
 |
In up-counting batch control, the Laureate counts up from
zero to a preset maximum. A prewarn level is available to slow down filling near the
preset to avoid overshoot. A time delay can be programmed from the end of each batch to
the start of the next batch. |
Down-Counting Batch Control |
 |
In down-counting batch control, the Laureate counts down
from the preset maximum to zero. A prewarn level is available to slow down filling or
emptying near zero. Again, a time delay can be programmed from the end of each batch to
the start of the next batch. |
Discrete Filling and Batch Counting |
 |
The Laureate batch controller is ideal for discrete
manufacturing as well as repetitive fill operations. In this example, the Laureate counts
bottles which it then groups into sixpacks. Its Grand Total capability can be used to
track bottles or sixpacks. |

Ordering
Guide
Laureate Pulse Input & Analog Input Batch
Controller
Click on the radio buttons to build a model number with pricing (shown below the Ordering Guide).
|